A horizontal venturimeter with inlet and throat diameters 30 cm and 15 cm is used to measure the flow of water. The reading of the differential mercury manometer connected to the inlet and the throat is 20 cm of mercury. Determine the rate of flow, taking C_{d} = 0.98 (answer in m^{3}/s).